APPENDICES
Appendix 4 Restrictions on Using MELSECNET/H Module in the Safety
CPU Module
App - 23
9
Device Explanation
10
CPU Module Processing
Time
11
Procedure for Writing
Program to CPU ModuleAppendices
Index
(2) Function of MELSECNET/H network system that can be used in the
safety CPU module
The function of MELSECNET/H network system and the function which can be used
in the safety CPU module are shown in TableApp.20.
: used,
: unused
TableApp.20 Function of MELSECNET/H network system and its availability in the safety CPU module
Function Use permitted/prohibited
Cyclic transmission function
Communication using LB/LW
Communication using LX/LY
MELSECNET/H extended mode
Refresh parameter
Common parameter
Station inherent parameter
Inter-link data transfer function
Designation of reserved station
Low-speed cyclic transmission function
Redundant system function
Transient transmission function
Communication function
Routing function
Group function
Message transmission function using logical channel numbers
Data sending/receiving (SEND/RECV)
Other station word device read/write (READ/SREAD/WRITE/SWRITE)
Other station transient request (REQ)
Other station word device read/write (ZNRD/ZNWR)
Remote RUN/Remote STOP (RRUN/RSTOP)
Reading and writing other station CPU module's clock data (RTMRD/
RTMWR)
RAS function
Automatic return function
Control station switch function
Control station return control function
Loopback function (optical loop system)
Prevention of station failure by using external power supply (Optical
loop system)
Station detach function (coaxial bus system)
Transient transmission enabled even at CPU module error
Checking transient transmission abnormal detection time
Diagnostic function
Direct access to link devices
Starting interrupt sequence program
Multiplex transmission function (optical loop system)
Simple dual-structured network
Stopping/restarting of cyclic transmission and stopping link refresh (network test)
Increasing number of send points by installing multiple modules with the same network number
Multiple CPU system supported
Remote I/O network system.
Redundant system supported
Network diagnostic (line monitor)