Back to Basics SM600 Bedienungsanleitung Seite 220

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 234
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 219
App - 18
Appendix 2 Special Register List
APPENDICES
TableApp.17 Special register
Number Name Meaning Explanation
Set by
(When set)
Corresponding
CPU
SD1076
to
SD1079
Safety station
interlock
cancel request
(CC-Link
Safety master
module 1)
0: Not cancel the
I/O interlock
of safety
station
1: Cancel the I/O
interlock of
safety station
Cancel the I/O interlock of safety station by changing the bit of
register from 0 to 1.
1 to 64 in the table indicate station numbers.
U (Request)
QS
SD1200
to
SD1203
Safety remote
station
specification
(CC-Link
Safety master
module 2)
0: No safety
remote station
specification
1: Safety remote
station
specification
The specified status of safety remote station is stored.
"0" is stored for the standard remote station.
1 to 64 in the table indicate station numbers.
S (Initial)
SD1204
to
SD1207
Safety station
refresh
communication
status (CC-Link
Safety master
module 2)
0: Normal,
Reserved
station
specified,
Unused,
Standard
remote station
1: Safety station
communication
error
The refresh communication status of safety remote station is
stored.
"0" is stored for the standard remote station.
1 to 64 in the table indicate station numbers.
S (Status
changel)
SD1208
to
SD1271
Safety station
communication
status (CC-Link
Safety master
module 2)
The status of
communication
with safety
station is stored.
The status of communication with each safety remote station
is stored.
SD1208: Station number 1 to SD1271: Station number 64 (0
fixed in the case of standard remote station, reserved station
specified, or without connection)
0: At normal communication
10: At initial
20: During internal information access
30: Link error
8300: Link error (Safety remote station detection error)
8310: Link error (Product information mismatch)
8320: Link error (Initial monitor timeout)
8321: Link error (Safety monitor timeout)
8322: Link error (Error monitor timeout)
8330: Link error (Command error)
8331: Link error (Data numbering error)
8332: Link error (Link ID error)
8333: Link error (Running number error)
8334: Link error (Received data error)
S (Status
changel)
SD1076
SD1077
SD1078
SD1079
16
32
48
64
15
31
47
63
to
to
to
to
2
18
34
50
1
17
33
49
b15 b14 - b1 b0
SD1000
SD1001
SD1002
SD1003
16
32
48
64
15
31
47
63
to
to
to
to
2
18
34
50
1
17
33
49
b15 b14 - b1 b0
SD1204
SD1205
SD1206
SD1207
16
32
48
64
15
31
47
63
to
to
to
to
2
18
34
50
1
17
33
49
b15 b14 - b1 b0
Seitenansicht 219
1 2 ... 215 216 217 218 219 220 221 222 223 224 225 ... 233 234

Kommentare zu diesen Handbüchern

Keine Kommentare